Skip to content

Demo on VLAB

The goal of this demo is to show how to use VPCs, attach and peer them and run test connectivity between the servers. Examples are based on the default VLAB topology.

You can find instructions on how to setup VLAB in the Overview and Running VLAB sections.

Default topology

The default topology is Spine-Leaf with 2 spines, 2 MCLAG leaves and 1 non-MCLAG leaf. Optionally, you can choose to run the default Collapsed Core topology using flag --fabric-mode collapsed-core (or -m collapsed-core) which only consists of 2 switches.

For more details on customizing topologies see the Running VLAB section.

In the default topology, the following Control Node and Switch VMs are created:

graph TD
    CN[Control Node]

    S1[Spine 1]
    S2[Spine 2]

    L1[MCLAG Leaf 1]
    L2[MCLAG Leaf 2]
    L3[Leaf 3]

    CN --> L1
    CN --> L2

    S1 --> L1
    S1 --> L2
    S2 --> L2
    S2 --> L3

As well as the following test servers:

graph TD
    L1[MCLAG Leaf 1]
    L2[MCLAG Leaf 2]
    L3[Leaf 3]
    L4[Leaf 4]

    TS1[Test Server 1]
    TS2[Test Server 2]
    TS3[Test Server 3]
    TS4[Test Server 4]
    TS5[Test Server 5]
    TS6[Test Server 6]

    TS1 --> L1
    TS1 --> L2

    TS2 --> L1
    TS2 --> L2

    TS3 --> L1
    TS4 --> L2

    TS5 --> L3
    TS6 --> L4

Creating and attaching VPCs

You can create and attach VPCs to the VMs using the kubectl fabric vpc command on the Control Node or outside of the cluster using the kubeconfig. For example, run the following commands to create 2 VPCs with a single subnet each, a DHCP server enabled with its optional IP address range start defined, and to attach them to some of the test servers:

core@control-1 ~ $ kubectl get conn | grep server
server-01--mclag--leaf-01--leaf-02   mclag          5h13m
server-02--mclag--leaf-01--leaf-02   mclag          5h13m
server-03--unbundled--leaf-01        unbundled      5h13m
server-04--bundled--leaf-02          bundled        5h13m
server-05--unbundled--leaf-03        unbundled      5h13m
server-06--bundled--leaf-03          bundled        5h13m

core@control-1 ~ $ kubectl fabric vpc create --name vpc-1 --subnet 10.0.1.0/24 --vlan 1001 --dhcp --dhcp-start 10.0.1.10
06:48:46 INF VPC created name=vpc-1

core@control-1 ~ $ kubectl fabric vpc create --name vpc-2 --subnet 10.0.2.0/24 --vlan 1002 --dhcp --dhcp-start 10.0.2.10
06:49:04 INF VPC created name=vpc-2

core@control-1 ~ $ kubectl fabric vpc attach --vpc-subnet vpc-1/default --connection server-01--mclag--leaf-01--leaf-02
06:49:24 INF VPCAttachment created name=vpc-1--default--server-01--mclag--leaf-01--leaf-02

core@control-1 ~ $ kubectl fabric vpc attach --vpc-subnet vpc-2/default --connection server-02--mclag--leaf-01--leaf-02
06:49:34 INF VPCAttachment created name=vpc-2--default--server-02--mclag--leaf-01--leaf-02

The VPC subnet should belong to an IPv4Namespace, the default one in the VLAB is 10.0.0.0/16:

core@control-1 ~ $ kubectl get ipns
NAME      SUBNETS           AGE
default   ["10.0.0.0/16"]   5h14m

After you created the VPCs and VPCAttachments, you can check the status of the agents to make sure that the requested configuration was applied to the switches:

core@control-1 ~ $ kubectl get agents
NAME       ROLE          DESCR           APPLIED   APPLIEDG   CURRENTG   VERSION
leaf-01    server-leaf   VS-01 MCLAG 1   2m2s      5          5          v0.23.0
leaf-02    server-leaf   VS-02 MCLAG 1   2m2s      4          4          v0.23.0
leaf-03    server-leaf   VS-03           112s      5          5          v0.23.0
spine-01   spine         VS-04           16m       3          3          v0.23.0
spine-02   spine         VS-05           18m       4          4          v0.23.0

In this example, the values in columns APPLIED and APPLIEDG are equal which means that the requested configuration has been applied.

Setting up networking on test servers

You can use hhfab vlab ssh on the host to SSH into the test servers and configure networking there. For example, for both server-01 (MCLAG attached to both leaf-01 and leaf-02) we need to configure a bond with a VLAN on top of it and for the server-05 (single-homed unbundled attached to leaf-03) we need to configure just a VLAn and they both will get an IP address from the DHCP server. You can use the ip command to configure networking on the servers or use the little helper preinstalled by Fabricator on test servers.

For server-01:

core@server-01 ~ $ hhnet cleanup
core@server-01 ~ $ hhnet bond 1001 enp2s1 enp2s2
10.0.1.10/24
core@server-01 ~ $ ip a
...
3: enp2s1: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast master bond0 state UP group default qlen 1000
    link/ether 06:5a:e8:38:3b:ea brd ff:ff:ff:ff:ff:ff permaddr 0c:20:12:fe:01:01
4: enp2s2: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast master bond0 state UP group default qlen 1000
    link/ether 06:5a:e8:38:3b:ea brd ff:ff:ff:ff:ff:ff permaddr 0c:20:12:fe:01:02
6: bond0: <BROADCAST,MULTICAST,MASTER,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000
    link/ether 06:5a:e8:38:3b:ea brd ff:ff:ff:ff:ff:ff
    inet6 fe80::45a:e8ff:fe38:3bea/64 scope link
       valid_lft forever preferred_lft forever
7: bond0.1001@bond0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000
    link/ether 06:5a:e8:38:3b:ea brd ff:ff:ff:ff:ff:ff
    inet 10.0.1.10/24 metric 1024 brd 10.0.1.255 scope global dynamic bond0.1001
       valid_lft 86396sec preferred_lft 86396sec
    inet6 fe80::45a:e8ff:fe38:3bea/64 scope link
       valid_lft forever preferred_lft forever

And for server-02:

core@server-02 ~ $ hhnet cleanup
core@server-02 ~ $ hhnet bond 1002 enp2s1 enp2s2
10.0.2.10/24
core@server-02 ~ $ ip a
...
3: enp2s1: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast master bond0 state UP group default qlen 1000
    link/ether 5e:10:b1:f7:d0:4c brd ff:ff:ff:ff:ff:ff permaddr 0c:20:12:fe:02:01
4: enp2s2: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast master bond0 state UP group default qlen 1000
    link/ether 5e:10:b1:f7:d0:4c brd ff:ff:ff:ff:ff:ff permaddr 0c:20:12:fe:02:02
8: bond0: <BROADCAST,MULTICAST,MASTER,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000
    link/ether 5e:10:b1:f7:d0:4c brd ff:ff:ff:ff:ff:ff
    inet6 fe80::5c10:b1ff:fef7:d04c/64 scope link
       valid_lft forever preferred_lft forever
9: bond0.1002@bond0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000
    link/ether 5e:10:b1:f7:d0:4c brd ff:ff:ff:ff:ff:ff
    inet 10.0.2.10/24 metric 1024 brd 10.0.2.255 scope global dynamic bond0.1002
       valid_lft 86185sec preferred_lft 86185sec
    inet6 fe80::5c10:b1ff:fef7:d04c/64 scope link
       valid_lft forever preferred_lft forever

Testing connectivity before peering

You can test connectivity between the servers before peering the switches using the ping command:

core@server-01 ~ $ ping 10.0.2.10
PING 10.0.2.10 (10.0.2.10) 56(84) bytes of data.
From 10.0.1.1 icmp_seq=1 Destination Net Unreachable
From 10.0.1.1 icmp_seq=2 Destination Net Unreachable
From 10.0.1.1 icmp_seq=3 Destination Net Unreachable
^C
--- 10.0.2.10 ping statistics ---
3 packets transmitted, 0 received, +3 errors, 100% packet loss, time 2003ms
core@server-02 ~ $ ping 10.0.1.10
PING 10.0.1.10 (10.0.1.10) 56(84) bytes of data.
From 10.0.2.1 icmp_seq=1 Destination Net Unreachable
From 10.0.2.1 icmp_seq=2 Destination Net Unreachable
From 10.0.2.1 icmp_seq=3 Destination Net Unreachable
^C
--- 10.0.1.10 ping statistics ---
3 packets transmitted, 0 received, +3 errors, 100% packet loss, time 2004ms

Peering VPCs and testing connectivity

To enable connectivity between the VPCs, peer them using kubectl fabric vpc peer:

core@control-1 ~ $ kubectl fabric vpc peer --vpc vpc-1 --vpc vpc-2
07:04:58 INF VPCPeering created name=vpc-1--vpc-2

Make sure to wait until the peering is applied to the switches using kubectl get agents command. After that, you can test connectivity between the servers again:

core@server-01 ~ $ ping 10.0.2.10
PING 10.0.2.10 (10.0.2.10) 56(84) bytes of data.
64 bytes from 10.0.2.10: icmp_seq=1 ttl=62 time=6.25 ms
64 bytes from 10.0.2.10: icmp_seq=2 ttl=62 time=7.60 ms
64 bytes from 10.0.2.10: icmp_seq=3 ttl=62 time=8.60 ms
^C
--- 10.0.2.10 ping statistics ---
3 packets transmitted, 3 received, 0% packet loss, time 2004ms
rtt min/avg/max/mdev = 6.245/7.481/8.601/0.965 ms
core@server-02 ~ $ ping 10.0.1.10
PING 10.0.1.10 (10.0.1.10) 56(84) bytes of data.
64 bytes from 10.0.1.10: icmp_seq=1 ttl=62 time=5.44 ms
64 bytes from 10.0.1.10: icmp_seq=2 ttl=62 time=6.66 ms
64 bytes from 10.0.1.10: icmp_seq=3 ttl=62 time=4.49 ms
^C
--- 10.0.1.10 ping statistics ---
3 packets transmitted, 3 received, 0% packet loss, time 2004ms
rtt min/avg/max/mdev = 4.489/5.529/6.656/0.886 ms

If you delete the VPC peering with kubectl delete applied to the relevant object and wait for the agent to apply the configuration on the switches, you can observe that connectivity is lost again:

core@control-1 ~ $ kubectl delete vpcpeering/vpc-1--vpc-2
vpcpeering.vpc.githedgehog.com "vpc-1--vpc-2" deleted
core@server-01 ~ $ ping 10.0.2.10
PING 10.0.2.10 (10.0.2.10) 56(84) bytes of data.
From 10.0.1.1 icmp_seq=1 Destination Net Unreachable
From 10.0.1.1 icmp_seq=2 Destination Net Unreachable
From 10.0.1.1 icmp_seq=3 Destination Net Unreachable
^C
--- 10.0.2.10 ping statistics ---
3 packets transmitted, 0 received, +3 errors, 100% packet loss, time 2004ms

You can see duplicate packets in the output of the ping command between some of the servers. This is expected behavior and is caused by the limitations in the VLAB environment.

core@server-01 ~ $ ping 10.0.5.10
PING 10.0.5.10 (10.0.5.10) 56(84) bytes of data.
64 bytes from 10.0.5.10: icmp_seq=1 ttl=62 time=9.58 ms
64 bytes from 10.0.5.10: icmp_seq=1 ttl=62 time=9.58 ms (DUP!)
64 bytes from 10.0.5.10: icmp_seq=2 ttl=62 time=6.99 ms
64 bytes from 10.0.5.10: icmp_seq=2 ttl=62 time=6.99 ms (DUP!)
64 bytes from 10.0.5.10: icmp_seq=3 ttl=62 time=9.59 ms
64 bytes from 10.0.5.10: icmp_seq=3 ttl=62 time=9.60 ms (DUP!)
^C
--- 10.0.5.10 ping statistics ---
3 packets transmitted, 3 received, +3 duplicates, 0% packet loss, time 2003ms
rtt min/avg/max/mdev = 6.987/8.720/9.595/1.226 ms

Using VPCs with overlapping subnets

First, create a second IPv4Namespace with the same subnet as the default one:

core@control-1 ~ $ kubectl get ipns
NAME      SUBNETS           AGE
default   ["10.0.0.0/16"]   24m

core@control-1 ~ $ cat <<EOF > ipns-2.yaml
apiVersion: vpc.githedgehog.com/v1alpha2
kind: IPv4Namespace
metadata:
  name: ipns-2
  namespace: default
spec:
  subnets:
  - 10.0.0.0/16
EOF

core@control-1 ~ $ kubectl apply -f ipns-2.yaml
ipv4namespace.vpc.githedgehog.com/ipns-2 created

core@control-1 ~ $ kubectl get ipns
NAME      SUBNETS           AGE
default   ["10.0.0.0/16"]   30m
ipns-2    ["10.0.0.0/16"]   8s

Let's assume that vpc-1 already exists and is attached to server-01 (see Creating and attaching VPCs). Now we can create vpc-3 with the same subnet as vpc-1 (but in the different IPv4Namespace) and attach it to the server-03:

core@control-1 ~ $ cat <<EOF > vpc-3.yaml
apiVersion: vpc.githedgehog.com/v1alpha2
kind: VPC
metadata:
  name: vpc-1
  namespace: default
spec:
  ipv4Namespace: ipns-2
  subnets:
    default:
      dhcp:
        enable: true
        range:
          start: 10.0.1.10
      subnet: 10.0.1.0/24
      vlan: "2001"
  vlanNamespace: default
EOF

core@control-1 ~ $ kubectl apply -f vpc-3.yaml